Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
J Orthop ; 54: 163-167, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38605902

ABSTRACT

Introduction: Total knee arthroplasty (TKA) is a complex surgical procedure that traditionally relies on two-dimensional radiographs for pre-operative planning. These radiographs may not capture the intricate details of individual knee anatomy, potentially limiting the precision of surgical interventions. With advancements in imaging technology, there is an opportunity to refine TKA outcomes. This study introduces the Native Alignment Phenotype classification system that is based on pre-operative 3-dimensional computed tomography (CT) scans, aiming to provide a more detailed understanding of knee deformities and their influence on characterizing knee osteoarthritis and planning for TKA procedures. Methods: There were 1406 pre-operative non-weight-bearing CT scans analyzed by a single surgeon experienced with robotically-assisted total knee arthroplasties. These scans were converted into three-dimensional models, focusing on the coronal and sagittal planes. Intraoperatively, the robotic system was used to capture native coronal and sagittal deformities for each patient. These values were captured with the patient's leg held in a non-stress, extension pose. A new classification system, 'The Native Alignment Phenotype', was developed to categorize the specific differences between individual knees. Results: There were four primary knee malalignments identified: varus deformity; valgus deformity; and two deformities in the sagittal plane. These malalignments were further categorized based on the degrees of deviation, creating groups with 5° coronal and sagittal ranges. A total of 77 phenotypic alignment patterns were found based on the analyzed cohort. In the coronal plane, varus HKA deformity between 6 and 10° was the most common, with 36.9% of the cases, followed by varus HKA alignment, which was between 0 and 5°, representing 34.3% of the cases. In the sagittal plane, neutral and flexion contracture deformities between 0 and 5° were the most common, with 32.6% of the cases, followed by a fixed flexion contracture alignment, which was between 6 and 10°, representing 28.7% of the cases. When combining coronal and sagittal planes, the most common alignment was the varus between 0 and 5° with a flexion contracture between 0 and 5° (12.5% of cases), closely followed by the varus between 6 and 10° with a flexion contracture between 6 and 10° (12.4% of cases). Conclusion: The Native Alignment Phenotype classification system offers a nuanced understanding of knee deformities based on three-dimensional (CT scan) assessments, potentially leading to improved surgical outcomes in TKA. By leveraging the detailed data from the CT scans, this system provides a more comprehensive view of the knee's anatomy, emphasizing the importance of individualized, data-driven approaches in knee surgery.

2.
Surg Technol Int ; 442024 04 04.
Article in English | MEDLINE | ID: mdl-38573818

ABSTRACT

BACKGROUND: Shorter, metaphyseal-filling collared stems have become popular with the direct anterior approach (DAA), based on their ease of broaching and insertion through less invasive surgical exposures. To aid with the DAA, robotic-assisted technology provides three-dimensional computed tomography (CT) preoperative planning and intraoperative guidance to accurately assess stem version. With other femoral stems, this has been shown to provide more accurate implant planning and improved patient outcomes. The purpose of this study was to understand femoral stem placement predictability and patient outcomes for a newly designed metaphyseal-filling collared stem system through a DAA in combination with a robotic-assisted system during a single surgeon's initial cases. MATERIALS AND METHODS: A single high-volume surgeon, experienced with robotic-assisted DAA total hip arthroplasty (THA), adopted the use of a metaphyseal-filling collared stem. Intraoperative data and patient outcomes up to six months postoperative were collected prospectively during the surgeon's first 123 cases. Student's t-tests (α=0.05) were used for statistical comparisons. Intraoperative and radiographic assessments were performed for all 123 cases. RESULTS: The estimated version with neck-cut view of the robotic-assisted system was 13.81 ± 3.81°. The final version measurement captured with the robotic-assisted system was 16.56 ± 6.61°. The difference between the estimated version and robotic-assisted measured version was, on average, 2.68 ± 5.7° (p<0.001). The femoral stem sat at the level of the calcar in all but five cases. There were no intraoperative or postoperative periprosthetic fractures. Patients reported significant improvements in reduced Hip dysfunction and Osteoarthritis Outcome Score for Joint Replacement (HOOS-JR), Patient-Reported Outcomes Measurement Information System (PROMIS 10), and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores throughout their six-month recovery process with no patients reporting a periprosthetic joint infection, fracture, or dislocation. CONCLUSION: The use of a metaphyseal-filling collared stem with robotic-assisted DAA resulted in adequate stem version when assessed visually and with CT scan assessments. Version estimation values were improved upon over visual assessments when using the robotic system that maps out the proximal femur and the improvement was also demonstrated when compared to the prior literature. This may also be related to the stem's collar providing a visual guide during stem placement posterior fill of this triple-tapered stem design. Although further follow up is needed to assess longer-term outcomes, at six months postoperatively, patients had significant improvements in patient-reported outcomes with all patients reporting minimal to no restrictions with their THA.

3.
Surg Technol Int ; 442024 03 07.
Article in English | MEDLINE | ID: mdl-38547432

ABSTRACT

INTRODUCTION: Classical neutral mechanical alignment in total knee arthroplasty (TKA) has been a standard paradigm, while more recently, other alignment schemas, such as kinematic, individualized, and functional, have been explored. This study aimed to investigate the effect of three-dimensional (3D) computed tomography (CT)-based surgical robotics inputs on a classically trained surgeon's TKA component positions and alignment targets over time. MATERIALS AND METHODS: Data from 1,394 consecutive robotically-assisted TKAs by a single surgeon from 2016 to 2020 were analyzed. Metrics collected included pre-balance planned implant component positions, final planned implant component positions after soft tissue balancing, and constitutional alignment from CT scans. Joint line obliquity was plotted against the arithmetic hip-knee angle (aHKA) using coronal plane alignment of the knee (CPAK). Three categories of alignment strategy were defined: true mechanical alignment (tMA), adjusted mechanical alignment (aMA), and no mechanical alignment (noMA). RESULTS: A shift to overall varus component positioning was observed over the years. Joint line obliquity according to CPAK showed a wider spread in later years, and the distribution of tibial and femoral coronal alignment angles expanded over time. CONCLUSION: The study revealed a change in alignment targets and final positioning of components away from neutral biomechanical axes in a large volume of TKAs by a single, classically trained surgeon over five years of using a robotic arm-assisted TKA system with CT-based planning. The most dominant factor for this change was the use of 3D CT planning, allowing the surgeon to assess patient-specific anatomy and plan accordingly. Outcome data is needed to determine if this change in behavior and surgical technique was beneficial. In summary, using a CT scan-based robotically assisted technique led to a gradual and complete shift from tMA to predominantly a non-mechanically aligned philosophy in TKA.

4.
J Orthop ; 46: 78-82, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37969228

ABSTRACT

Introduction: Several implant manufacturers have developed ultra-porous metal substrate acetabular components recently. Despite this, data on clinical and radiographic outcomes remain limited. Our study evaluated postoperative patient-reported outcome measures (PROMs) and radiographic analyses in patients fitted with a novel acetabular porous-coated component. Methods: A total of 152 consecutive patients underwent a total hip arthroplasty by a single orthopaedic surgeon. All patients underwent surgery utilizing the same CT-scan based robotic-assisted device with the same porous cementless acetabular shell. They received standardized postoperative physical therapy, rehabilitation, and pain protocols. Preoperatively, first postoperative visit, 6-months, 1-year, and 2-years, patients were evaluated based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) pain, physical function, and total scores; 2) Patient-Reported Outcomes Measurement Information System (PROMIS)-10 physical and mental scores; 3) Hip Disability and Osteoarthritis Outcome Score (HOOS)-Jr scores; as well as 4) acetabular component positions and 5) evidence of acetabular component loosening. Results: Significant improvements were observed by 6 months in WOMAC pain, physical function, and total scores (p < 0.05), maintained at 1 and 2 years. PROMIS-10 physical scores also improved significantly from preoperative to 6 months postoperative and remained so at 1 and 2 years postoperative (p < 0.05). No significant changes were found in PROMIS-10 mental scores. HOOS-Jr scores significantly improved from preoperative to 6 months postoperative and remained so through 2 years (p < 0.05). At 6 months, slight changes were noted in abduction angle and horizontal and vertical offset. Radiolucencies, initially found in 3 shells, reduced to 1 shell with 2 new radiolucencies by 6 months, and remained stable with no subsequent operative interventions. At 1 year and 2 years, no radiographic abnormalities were noted, including complete resolution of prior radiolucencies as well as stable components. Conclusion: This porous cementless acetabular shell, implanted with CT-scan-based robotic-assisted techniques, demonstrated excellent postoperative PROMs at 2 years. Stable radiolucencies suggest good component stability. The early stable clinical and radiographic results suggest promising long-term outcomes with this device. Level of evidence: III (retrospective cohort study).

5.
Surg Technol Int ; 432023 11 16.
Article in English | MEDLINE | ID: mdl-37972545

ABSTRACT

The use of robotic-assisted total hip arthroplasty and three-dimensional computed tomography scan-based templating has become increasingly popular over the last 10 years. However, proper planning and execution are vital to producing optimal patient outcomes. In order to achieve these outcomes, the robotic-assisted system requires training, familiarity, and experience. The goal of this article is to provide clear and condensed examples of preoperative planning, as well as adjustments that one can make to avoid impingement. The surgical technique for robotic-assisted total hip arthroplasty is also briefly discussed. Examples will be given using the latest computed tomography (CT) scan-based robotic platform for osteoarthritic hips, with specific examples of various cases of impingement that might be encountered by the surgeon and how to ultimately avoid this problem when performing the arthroplasty. This article, through case histories, will discuss the various principles and adjustments that can be made to place components in the ideal location based on individual anatomy.

6.
Surg Technol Int ; 422023 06 14.
Article in English | MEDLINE | ID: mdl-37311569

ABSTRACT

The utilization of robotic-arm assisted unicompartmental knee arthroplasty (UKA) or partial knee arthroplasty (PKA) for the treatment of medial unicompartmental osteoarthritis has continued to increase. This is in part due to the consistently reproducible accuracy and precision of implant planning, intra-operative ligament balancing software, tracking optimization software, robotic-arm assisted bone preparation, excellent survivorship rates, and improvements in many patient-reported outcomes compared to manual UKA, using the Stryker Mako™ Robotic Partial Knee System (Stryker, Mako Surgical Corp., Mahwah, New Jersey). Training in the utilization of robotic-arm assistance can be time-consuming and comes with an associated learning curve even after the in-person training and coursework is complete, like most procedures. Therefore, our aim was to describe the pre-operative planning and intra-operative surgical technique for using a robotic-arm assisted partial knee system for UKA/PKA in patients who have unicompartmental medial knee osteoarthritis. Specifically, we will discuss: 1) pre-operative planning; 2) operative setup; 3) intra-operative steps; 4) execution of the plan; and 5) trialing, implantation, and final assessments.

7.
Int Orthop ; 47(5): 1243-1247, 2023 05.
Article in English | MEDLINE | ID: mdl-36864185

ABSTRACT

PURPOSE: Pelvic tilt (PT) is important to consider when planning total hip arthroplasty (THA) due to its dynamic impact on acetabular orientation. The degree of sagittal pelvic rotation varies during functional activities and can be difficult to measure without proper imaging. The purpose of this study was to evaluate PT variation in the supine, standing, and seated positions. METHODS: A multi-centre cross-sectional study was performed that included 358 THA patients who had preo-perative PT measured from supine CT scan and standing and upright seated lateral radiographs. Supine, standing, and seated PT and associated changes between functional positions were evaluated. Anterior PT was assigned a positive value. RESULTS: In the supine position, mean PT was 4° (range, -35° to 20°), where 23% had posterior PT and 69% anterior PT. In the standing position, mean PT was 1° (range, -23° to 29°), where 40% had posterior PT and 54% anterior PT. In the seated position, mean PT was -18° (range, -43° to 47°), where 95% had posterior PT and 4% anterior PT. From standing to seated, the pelvis rotated posteriorly in 97% of cases (maximum 60°) with 16% of cases considered stiff (change ≤ 10°) and 18% of cases considered hypermobile (change ≥ 30°). CONCLUSION: Patients undergoing THA have marked PT variation in the supine, standing, and seated positions. There was wide variability in PT change from standing to seated, with 16% of patients considered stiff and 18% considered hypermobile. Functional imaging should be performed on patients prior to THA to allow for more accurate planning.


Subject(s)
Arthroplasty, Replacement, Hip , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Cross-Sectional Studies , Acetabulum/diagnostic imaging , Acetabulum/surgery , Posture , Pelvis/surgery
8.
J Knee Surg ; 36(14): 1462-1466, 2023 Dec.
Article in English | MEDLINE | ID: mdl-36657463

ABSTRACT

Computed tomography (CT) scan-based three-dimensional (3D) modeling operative technology has been shown to improve upon results of manual total knee arthroplasties (TKAs). Although there are many reports on superior precision of this CT-based technology, there has been continuing interest regarding extended clinical outcomes. The purpose of this study was to compare their clinical outcomes with manual TKAs at approximately 3-year follow-up. Specifically, we analyzed: (1) survivorship, (2) functional outcomes, (3) complications, and (4) radiographic outcomes (i.e., alignment, progressive radiolucencies). A total of 210 patients receiving CT-based TKAs performed by a single surgeon at a single center between July 1, 2016, and February 16, 2018, were compared with 210 manual TKAs completed by the same surgeon immediately preceding implementation of the CT-based technology. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) surveys were collected at ∼3 years postoperatively. Subgroup analyses of pain and physical function scores were performed. Follow-up radiographs were evaluated for alignment, loosening, and/or progressive radiolucencies. There was 100% survivorship at final follow-up. The postoperative mean pain scores for the CT-based cohort and manual cohort were 1 ± 2 (range, 0-14) and 2 ± 3 (range, 0-17), respectively (p < 0.05). The postoperative mean physical function scores for the CT-based cohort and manual cohort were 3 ± 4 (range, 0-18) and 5 ± 5 (range, 0-19), respectively (p < 0.05). The postoperative mean total WOMAC scores for the CT-based cohort and manual cohort were 5 ± 4 (range, 0-32) and 7 ± 8 (range, 0-35), respectively (p < 0.05). There were low numbers of postoperative complications at final follow-up in either cohort. None exhibited progressive radiolucencies by final follow-up. The 3-year postoperative clinical outcomes support excellent survivorship and radiographic outcomes, low complication rates, as well as improved pain, physical function, and total WOMAC scores for CT-based TKAs. Therefore, patients who undergo CT-based 3D modeling TKAs should expect to have superior long-term clinical outcomes.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Knee Joint/diagnostic imaging , Knee Joint/surgery , Treatment Outcome , Pain, Postoperative , Tomography, X-Ray Computed , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Follow-Up Studies
9.
J Knee Surg ; 36(8): 873-877, 2023 Jul.
Article in English | MEDLINE | ID: mdl-35255506

ABSTRACT

Robotic-assisted total knee arthroplasty (RA-TKA) has been shown to improve the accuracy of bone resection, reduce radiographic outliers, and decrease iatrogenic injury. However, it has also been shown that RA-TKA surgical times can be longer than manual surgery during adoption. The purpose of this article was to investigate (1) the characteristics of the operative time curves and trends, noting the amount of surgeons who improved, for those who performed at least 12 cases (based on initial modeling); (2) the proportion of RA surgeons who achieved the same operative times for RA-TKA as compared with manual TKAs; and (3) the number of RA-TKA cases until a steady-state operative time was achieved. TKA operative times were collected from 30 hospitals for 146 surgeons between January 1, 2016, and December 31, 2019. A hierarchical Bayesian model was used to estimate the difference between the mean RA-TKA times by case interval and the weighted baseline for manual times. The learning curve was observed at the 12th case. Therefore, operative times were analyzed for each surgeon who performed at least 12 RA-TKA cases to determine the percentage of these surgeons who trended toward a decrease or increase in their times. These surgeons were further analyzed to determine the proportion who achieved the same operating times as manual TKAs. A further hierarchical Bayesian model was used to determine when these surgeons achieved steady-state operative times. There were 60 surgeons (82%) who had decreasing surgical times over the first 12 RA-TKA cases. The remaining 13 (18%) had increasing surgical times (mean increase of 0.59 minutes/case). Approximately two-thirds of the surgeons (64%) achieved the same operating times as manual cases. The steady-state time neutrality occurred between 15 and 20 cases and beyond. This study demonstrated the learning curve for a large cohort of RA-TKAs. This model demonstrated a learning curve between 15 and 20 cases and beyond. These are important findings for this innovative technology.


Subject(s)
Arthroplasty, Replacement, Knee , Robotic Surgical Procedures , Surgeons , Humans , Learning Curve , Bayes Theorem , Knee Joint/surgery
10.
J Knee Surg ; 36(2): 159-166, 2023 Jan.
Article in English | MEDLINE | ID: mdl-34187064

ABSTRACT

Robotic-assisted technology has been developed to optimize the consistency and accuracy of bony cuts, implant placements, and knee alignments for total knee arthroplasty (TKA). With recently developed designs, there is a need for the reporting longer than initial patient outcomes. Therefore, the purpose of this study was to compare manual and robotic-assisted TKA at 2-year minimum for: (1) aseptic survivorship; (2) reduced Western Ontario and McMaster Universities Osteoarthritis Index (r-WOMAC) pain, physical function, and total scores; (3) surgical and medical complications; and (4) radiographic assessments for progressive radiolucencies. We compared 80 consecutive cementless robotic-assisted to 80 consecutive cementless manual TKAs. Patient preoperative r-WOMAC and demographics (e.g., age, sex, and body mass index) were not found to be statistically different. Surgical data and medical records were reviewed for aseptic survivorship, medical, and surgical complications. Patients were administered an r-WOMAC survey preoperatively and at 2-year postoperatively. Mean r-WOMAC pain, physical function, and total scores were tabulated and compared using Student's t-tests. Radiographs were reviewed serially throughout patient's postoperative follow-up. A p < 0.05 was considered significant. The aseptic failure rates were 1.25 and 5.0% for the robotic-assisted and manual cohorts, respectively. Patients in the robotic-assisted cohort had significantly improved 2-year postoperative r-WOMAC mean pain (1 ± 2 vs. 2 ± 3 points, p = 0.02), mean physical function (2 ± 3 vs. 4 ± 5 points, p = 0.009), and mean total scores (4 ± 5 vs, 6 ± 7 points, p = 0.009) compared with the manual TKA. Surgical and medical complications were similar in the two cohorts. Only one patient in the manual cohort had progressive radiolucencies on radiographic assessment. Robotic-assisted TKA patients demonstrated improved 2-year postoperative outcomes when compared with manual patients. Further studies could include multiple surgeons and centers to increase the generalizability of these results. The results of this study indicate that patients who undergo robotic-assisted TKA may have improved 2-year postoperative outcomes.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Robotic Surgical Procedures , Humans , Arthroplasty, Replacement, Knee/adverse effects , Robotic Surgical Procedures/methods , Follow-Up Studies , Treatment Outcome , Knee Joint/surgery , Pain, Postoperative/etiology
11.
J Knee Surg ; 36(13): 1386-1390, 2023 Nov.
Article in English | MEDLINE | ID: mdl-36564042

ABSTRACT

Many studies involving robotic-assisted total knee arthroplasty (RATKA) have demonstrated superiority regarding soft tissue balance and consistency with alignment target achievement. However, studies investigating whether RATKA is associated with improved patient outcomes regarding physical function and pain are also important. Therefore, we performed a cluster analysis and examined factors that contributed to differences in patient-reported outcome measures (PROMs). Specifically, we analyzed: (1) reduced WOMAC (rWOMAC) scores regarding pain and function; (2) usage of RATKA; (3) common patient comorbidities; as well as (4) patient demographic factors. The rWOMAC score is an abbreviated PROM that includes pain and physical function domains. This study analyzed 853 patients (95 conventional and 758 robotic-assisted) who had completed preoperative, 6-month, and 1-year postoperative rWOMAC surveys. Two clusters were constructed using rWOMAC pain and function scores at 1 year. Cluster 1 included 753 patients who had better outcomes at 1 year (mean rWOMAC pain = 0.9, mean rWOMAC function = 1.4), and cluster 2 included 100 patients who had worse outcomes at 1 year (mean rWOMAC pain = 7.7, mean rWOMAC function = 10.4). The clusters were compared to determine (1) how scores improved and (2) what patient characteristics were significantly different between clusters. Cluster 1 demonstrated greater improvement from preoperative to 6 months or 1 year (p = 0.0013 for pain preoperative to 6 months, p< 0.0001 for other measures) and 6 months to 1 year (p< 0.0001). Comparisons demonstrated that cluster 1 had older patients (67 vs. 65 years, p = 0.0479) who had lower body mass index or BMIs (31.8 vs. 33.9 kg/m2, p = 0.0042) and no significant differences in sex (p = 0.7849). Cluster 1 also had a significantly higher percentage of RATKA patients (90 vs. 79%, p< 0.001). Cluster analyses provided differentiating factors which were associated with improved postoperative rWOMAC pain and function scores at 1 year. Patients undergoing robotic-assisted TKA were associated with better rWOMAC pain and function scores from preoperative to 6 months and 1 year.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/adverse effects , Pain, Postoperative/etiology , Comorbidity , Patient Reported Outcome Measures , Cluster Analysis , Osteoarthritis, Knee/surgery , Knee Joint/surgery , Treatment Outcome
12.
Bone Jt Open ; 3(8): 589-595, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35848995

ABSTRACT

AIMS: The aim of this study was to report patient and clinical outcomes following robotic-assisted total knee arthroplasty (RA-TKA) at multiple institutions with a minimum two-year follow-up. METHODS: This was a multicentre registry study from October 2016 to June 2021 that included 861 primary RA-TKA patients who completed at least one pre- and postoperative patient-reported outcome measure (PROM) questionnaire, including Forgotten Joint Score (FJS), Knee Injury and Osteoarthritis Outcomes Score for Joint Replacement (KOOS JR), and pain out of 100 points. The mean age was 67 years (35 to 86), 452 were male (53%), mean BMI was 31.5 kg/m2 (19 to 58), and 553 (64%) cemented and 308 (36%) cementless implants. RESULTS: There were significant improvements in PROMs over time between preoperative, one- to two-year, and > two-year follow-up, with a mean FJS of 17.5 (SD 18.2), 70.2 (SD 27.8), and 76.7 (SD 25.8; p < 0.001); mean KOOS JR of 51.6 (SD 11.5), 85.1 (SD 13.8), and 87.9 (SD 13.0; p < 0.001); and mean pain scores of 65.7 (SD 20.4), 13.0 (SD 19.1), and 11.3 (SD 19.9; p < 0.001), respectively. There were eight superficial infections (0.9%) and four revisions (0.5%). CONCLUSION: RA-TKA demonstrated consistent clinical results across multiple institutions with excellent PROMs that continued to improve over time. With the ability to achieve target alignment in the coronal, axial, and sagittal planes and provide intraoperative real-time data to obtain balanced gaps, RA-TKA demonstrated excellent clinical outcomes and PROMs in this patient population.Cite this article: Bone Jt Open 2022;3(7):589-595.

13.
Surg Technol Int ; 40: 391-395, 2022 May 19.
Article in English | MEDLINE | ID: mdl-35415836

ABSTRACT

INTRODUCTION: Computed tomography scan (CT)-based three-dimensional (3D) modeling operative technologies have been shown to improve upon many perioperative results of manual total knee arthroplasties (TKAs). Although patient satisfaction has been reported for CT-based TKAs, studies evaluating large cohorts are limited. The purpose of this study was to compare the clinical outcomes of a surgeon's first 1,000 CT-based TKAs with manual TKAs during a minimum follow-up time of approximately six months. Specifically, we analyzed: (1) survivorship; (2) functional outcomes; (3) radiographic outcomes (i.e., alignment, progressive radiolucencies); and (4) complications. MATERIALS AND METHODS: A total of 1,000 consecutive primary CT-based total knee arthroplasty cases (988 patients) performed by a single surgeon at a single center between July 1, 2016 and July 1, 2021 were compared to a total of 1,000 consecutive manual TKAs (996 patients) completed by the same surgeon between May 18, 2013 and July 1, 2016. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) surveys were collected at approximately six months postoperatively. Subgroup analyses were performed on the physical function and pain scores. Follow-up radiographs were also examined for alignment, progressive radiolucencies, and/or loosenings. RESULTS: There was 100% survivorship at approximately six months follow up. The mean physical function score for the manual cohort and CT-based cohort were 10 ± 4 (range, 0 to 32) and 5 ± 4 (range, 0 to 22), respectively (p<0.05). The mean pain score for the manual cohort and CT-based cohort were 4 ± 4 (range, 0 to 20) and 3 ± 2 (range, 0 to 15), respectively (p<0.05). The mean total WOMAC score for the manual cohort and CT-based cohort were 13 ± 9 (range, 0 to 44) and 8 ± 7 (range, 0 to 33), respectively (p<0.05). None of the manual or CT-based cases exhibited progressive radiolucencies by final follow up. There were no postoperative medical and/or surgical complications at final follow up in the two cohorts. DISCUSSION/CONCLUSIONS: The 1,000 CT-based TKA clinical outcomes from this study continue to support great survivorship and radiographic outcomes, minimal complications, as well as improved physical function, pain, and total WOMAC scores. Therefore, those who undergo CT-based 3D modeling total knee arthroplasties should have the advantage of superior patient satisfaction.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Surgeons , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Humans , Knee Joint/surgery , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Pain , Patient Satisfaction , Tomography, X-Ray Computed , Treatment Outcome
14.
Int J Technol Assess Health Care ; 38(1): e19, 2022 Feb 07.
Article in English | MEDLINE | ID: mdl-35129112

ABSTRACT

OBJECTIVE: The purpose of this study was to systematically review the process for topic selection by health technology assessment (HTA) agencies around the world to provide the knowledge base for the improvement of topic selection frameworks in HTA agencies. METHODS: A systematic search was conducted in PubMed and EMBASE to identify papers up to February 2019. Gray literature was identified by screening the Web sites of HTA agencies on the nonprofit member list of the International Network of Agencies for Health Technology Assessment (INAHTA). Data were extracted for each HTA agency and synthesized, with issues including general contextual information about each agency and the process of topic selection. RESULTS: Out of forty-nine nonprofit members of INAHTA, a total of seventeen HTA agencies with a framework for topic selection were identified from twenty-two included papers/documents. Multiple criteria were used for topic selection in all frameworks and agencies undertook multiple steps, which could include the specification of criteria for topic selection, identification of topics, short listing of potential topics, scoping of potential topics, scoring and ranking of potential topics, and deliberation and decision on final topics for HTA. Shortcomings were found in relation to methods of scoring and ranking as well as lack of monitoring and the evaluation of the process. CONCLUSIONS: Our study provides insights into the current practice of topic selection in HTA agencies. Multiple criteria decision analysis methodology appears highly relevant to these processes. A consensus approach for the development of methods of topic selection would be valuable for the HTA community.


Subject(s)
International Agencies , Technology Assessment, Biomedical
15.
J Knee Surg ; 35(4): 409-415, 2022 Mar.
Article in English | MEDLINE | ID: mdl-32838457

ABSTRACT

The learning curve has been established for robotic-assisted total knee arthroplasty (RATKA) during the first month of use; however, there have been no studies evaluating this on a longer term. Therefore, the purpose of this study was to compare operative times for three cohorts during the first year following adoption of RATKA (initial, 6 months, and 1 year) and a prior cohort of manual TKA. We investigated both mean operative times and the variability of operative time in each cohort. This is a learning curve study comparing a single surgeon's experience using RAKTA. The study groups were made up of two cohorts of 60 cementless RATKAs performed at ∼6 months and 1 year of use. A learning curve was created based on the mean operative times and individual operative times were stratified into different cohorts for comparison. Study groups were compared with the surgeon's initial group of 20 cemented RATKAs and 60 cementless manual cases. Descriptive numbers were compiled and mean operative times were compared using Student's t-tests for significant differences with a p-value of < 0.05. The mean surgical times continued to decrease after 6 months of RATKA. In 1 year, the surgeon was performing 88% of the RATKA between 50 and 69 minutes. The initial cohort and 1-year robotic-assisted mean operative times were 81 and 62 minutes, respectively (p < 0.00001). Mean 6-month robotic-assisted operative times were similar to manual times (p = 0.12). A significant lower time was found between the mean operative times for the 1-year robotic-assisted and manual (p = 0.008) TKAs. The data show continued improvement of operative times at 6 months and 1 year when using this new technology. The results of this study are important because they demonstrate how the complexity of a technology which initially increases operative time can be overcome and become more time-effective than conventional techniques.


Subject(s)
Arthroplasty, Replacement, Knee , Robotic Surgical Procedures , Surgeons , Arthroplasty, Replacement, Knee/methods , Humans , Knee Joint/surgery , Learning Curve , Robotic Surgical Procedures/methods
16.
J Knee Surg ; 35(14): 1587-1594, 2022 Dec.
Article in English | MEDLINE | ID: mdl-33932948

ABSTRACT

Advanced imaging used in robotic-assisted total knee arthroplasty (TKA), such as computed tomography (CT)-based three-dimensional (3D) planning, may provide an accurate means of implant sizing preoperatively. The purpose of this study was to examine preoperative CT-based implant planning accuracy for robotic-assisted TKA in patients who have (1) varus deformities, (2) valgus deformities, (3) neutral alignment, and (4) retained hardware. A total of 393 patients underwent a robotic-assisted TKA by a single surgeon received preoperative CT scans. The surgeon reviewed the CT-based model preoperatively and recorded the expected size of the components. The final implants used in each case were recorded and compared with the surgeon's preoperative plan. In all groups of patients, the surgeon's CT-based implant plan was within one size of the implant utilized 100% of the time for both the tibiae and femora. Overall, the surgeon was exactly matched in 319 (81%) and 315 (80%) cases for the femoral and tibial components, respectively. For the femoral component, the mean age for patients in whom the original plan was exactly matched was younger than those whose implants were upsized and older than patients those implants were downsized (p = 0.024). Other patient demographics and preoperative knee alignment were not associated with predictive accuracy for femoral or tibial components. Our results demonstrate how preoperative CT-based, 3D planning for robotic-assisted TKA is accurate to within one size of the components in every case (100%), and exactly matched in 80%. The results of this study are important because they demonstrate how CT-based preoperative implant planning for TKA is reliable and accurate across all native knee alignments and other patient-specific factors. In addition, they build on a previous study by the same single surgeon, demonstrating that predictive ability can improve over time. This may be important as we move toward more outpatient surgery with less ability for prostheses inventory at ambulatory sites.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Robotic Surgical Procedures , Humans , Arthroplasty, Replacement, Knee/methods , Robotic Surgical Procedures/methods , Knee Joint/diagnostic imaging , Knee Joint/surgery , Tomography, X-Ray Computed
17.
Surg Technol Int ; 39: 389-393, 2021 07 26.
Article in English | MEDLINE | ID: mdl-34312827

ABSTRACT

INTRODUCTION: Valgus knee deformities can sometimes be challenging to address during total knee arthroplasties (TKAs). While appropriate surgical technique is often debated, the role of new operative technologies in addressing these complex cases has not been clearly established. The purpose of this study was to analyze the usefulness of computed tomography scan (CT)-based three-dimensional (3D) modeling operative technology in assisting with TKA planning, execution of bone cuts, and alignment. Specifically, we evaluated valgus TKAs performed using this CT-based technology for: (1) intraoperative implant plan, number of releases, and surgeon prediction of component size; (2) survivorship and clinical outcomes at a minimum follow up of one year; and (3) radiographic outcomes. MATERIALS AND METHODS: A total of 152 patients who had valgus deformities receiving a CT-based TKA performed by a single surgeon were analyzed. Cases were performed using an enhanced preoperative planning and real-time intraoperative feedback and cutting tool. The surgeon predicted and recorded implant sizes preoperatively and all patients received implants with initial and final implant alignment, flexion/extension gaps, and full or partial soft tissue releases recorded. A modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR.) scores were collected preoperatively and at approximately six months and one year postoperatively. Preoperative coronal alignment ranged from 1 to 13° valgus. Follow-up radiographs were also evaluated for alignments, loosenings, and/or progressive radiolucencies. RESULTS: A total of 96% of cases were corrected to within 3° of mechanical neutral. For outlier cases, initial deformities ranged from valgus 5 to 13°, with final alignment ranging from 4 to 8° valgus (mean 4° correction). Patients had mean femoral internal rotation of 2° and mean femoral flexion of 4°. The surgeon was within one size on the femur and tibia 94 and 100% of the time, respectively. Only one patient required a lateral soft tissue release and one patient had osteophytes removed, which required a medial soft tissue release. Five patients required manipulations under anesthesia. Aside from these, there were no postoperative medical and/or surgical complications and there was 100% survivorship at final follow up. WOMAC and KOOS, JR. scores improved significantly from a mean of 21 ± 9 and 48 ± 10 points preoperatively to 4 ± 6 (p<0.05) and 82 ± 15 (p<0.05) at final follow up, respectively. None of the cases exhibited progressive radiolucencies by final follow up. DISCUSSION: A limitation of this study was not evaluating dynamic kinematics in these patients to determine if rotation had any effects on kinematics. Future studies will evaluate this concern. Nevertheless, the technology successfully assisted with planning, executing bone cuts, and achieving alignment in TKAs complicated by the deformity. This may allow surgeons to predictably avoid soft tissue releases and accurately know component sizes preoperatively, while consistently achieving desired postoperative alignment. CONCLUSIONS: This study demonstrated the utility of CT-based 3D modeling techniques for challenging valgus deformity cases. Use of 3D modeling allowed the TKA components to be positioned according to the patient's anatomy in the coronal, transverse, and sagittal planes. When making these intraoperative implant adjustments, the surgeon may choose to place components outside the preoperative planning guidelines based on the clinical needs of the patient.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Femur/surgery , Humans , Knee , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Tibia/surgery
18.
Surg Technol Int ; 37: 390-394, 2020 Nov 28.
Article in English | MEDLINE | ID: mdl-33238024

ABSTRACT

INTRODUCTION: Malposition of THA implants can lead to many complications, some of which may necessitate reoperation. Thus, proper implant placement is critical for optimizing patient outcomes. In addition, intraoperative visual estimation of stem position has been shown to be unreliable. Therefore, the purpose of this study was to compare a surgeon's visual estimation of femoral version to the actual version captured using a three-dimensional robotic-arm assisted platform. MATERIALS AND METHODS: A prospective study of 25 THAs performed by a single surgeon was performed. The mean version, as estimated by intraoperative visual assessment, was compared to that measured by the robotic-arm assisted technology software using a two-sided t-test. Outliers were evaluated for the following intervals: 1 to 5°, 6 to 10°, and greater than 10°. A separate analysis was performed for anteverted versus retroverted stems. RESULTS: The mean version, as estimated by intraoperative visual assessment, was 9.16 ± 4.02° (range, 3 to 18°) compared to 3.52 ± 8.66° (range, -12 to 19) as measured by the robotic-arm assisted software (P=0.005). The surgeon's estimates of broach version and those measured by the robotic-arm assisted software were identical in three cases (12%). The evaluation methods differed by 1 to 5° in six cases (24%), 6 to 10° in 10 cases (40%), and greater than 10° in six cases (24%). Larger differences between methods were noted for cases in which the stem was found to be in anteversion by the robotic-arm assisted software. CONCLUSIONS: Visual estimation of femoral implant version differed significantly from measurements captured by three-dimensional robotic-arm assisted imaging. This suggests that estimating stem position intraoperatively by eye is not reliable, even when done by an experienced surgeon. The use of robotic-arm assisted technology may be recommended for determining femoral stem version intraoperatively.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Robotic Surgical Procedures , Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Humans , Prospective Studies
19.
Surg Technol Int ; 37: 349-355, 2020 Nov 28.
Article in English | MEDLINE | ID: mdl-33245139

ABSTRACT

INTRODUCTION: As bundle payments have begun focusing on orthopaedic procedures, particularly total knee arthroplasties (TKAs), surgeons and hospitals have evaluated methods for improving efficiency. Few studies have investigated the impact of novel, sealed-container and instrument-tray technology on turnover and costs. Therefore, the purpose of this study was to compare traditional and sealed container-sterilized TKA surgical trays by: 1) investigating the setup and clean-down time in the operating room (OR); 2) examining trays processing time in central sterile supply (CS); and 3) estimating OR and CS costs and waste produced. MATERIALS AND METHODS: An interdisciplinary team determined points throughout a TKA tray single-case life cycle that could cause variations in turnover time. The times were recorded for two different TKA tray configurations. Process A utilized instruments housed in vendor trays that were "blue" wrap sterilized, while Process B employed optimized trays that were sealed container-sterilized. Times were recorded during preoperative setup and postoperative clean down in the OR and CS. Reductions in mean OR or CS times were used to estimate cost savings. Wastes were analyzed for each method. Statistical analyses using Student t-tests were used to determine statistical differences and a p-value of less than 0.05 was considered significant. RESULTS: Overall, the use of optimized trays and sealed sterilization containers reduced the turnover time by 57 minutes and the number of trays by a mean of three. OR and CS processing yearly savings were estimated to be $249,245. Waste disposal was an estimated 10,590 ounces and 450 ounces for traditional and sealed containers, respectively. CONCLUSION: Novel sealed sterilization containers demonstrated increased efficiency in the total turnover time of TKA trays. This is important for surgeons participating in bundle payments who perform surgery in a hospital and ambulatory surgery center. Reduced turnover time could potentially increase case load and decrease the need for extra instrumentation or loaner trays. This simple means of increasing efficiency could be used as a model for surgeons wishing to streamline surgical trays and reduce costs.


Subject(s)
Surgical Instruments , Technology , Cost Savings , Humans , Operating Rooms , Orthopedic Procedures
20.
J Knee Surg ; 32(11): 1063-1068, 2019 Nov.
Article in English | MEDLINE | ID: mdl-30959549

ABSTRACT

Although there are many studies on the alignment advantages when using the robotic arm-assisted (RAA) system for total knee arthroplasty (TKA), there have been questions regarding patient-reported outcomes. Therefore, the purpose of this study was to use this index to compare: (1) total, (2) physical function, and (3) pain scores for manual versus RAA patients. We compared 53 consecutive RAA to 53 consecutive manual TKAs. No differences in preoperative scores were found between the cohorts. Patients were administered a modified Western Ontario and McMaster Universities Osteoarthritis Index satisfaction survey preoperatively and at 1-year postoperatively. The results were broken down to: (1) total, (2) physical function, and (3) pain scores. Univariate analysis with independent samples t-tests was used to compare 1-year postoperative scores. Multivariate models with stepwise backward linear regression were utilized to evaluate the associations between scores and surgical technique, age, sex, as well as body mass index (BMI). Statistical analyses were performed with a p < 0.05 to determine significance. The RAA cohort had significantly improved mean total (6 ± 6 vs. 9 ± 8 points, p = 0.03) and physical function scores (4 ± 4 vs. 6 ± 5 points, p = 0.02) when compared with the manual cohort. The mean pain score for the RAA cohort (2 ± 3 points [range, 0-14 points]) was also lower than that for the manual cohort (3 ± 4 points [range, 0-11 points]) (p = 0.06). On backward linear regression analyses, RAA was found to be significantly associated with more improved total (ß coefficient [ß] -0.208, standard error [SE] 1.401, p < 0.05), function (ß = 0.216, SE = 0.829, p < 0.05), and pain scores (ß -0.181, SE = 0.623, p = 0.063). The RAA technique was found to have the strongest association with improved scores when compared with age, gender, and BMI. This study suggests that RAA patients may have short-term improvements at minimum 1-year postoperatively. However, longer term follow-up with greater sample sizes is needed to further validate these results.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Osteoarthritis, Knee/surgery , Pain, Postoperative/epidemiology , Robotic Surgical Procedures/adverse effects , Aged , Aged, 80 and over , Cohort Studies , Female , Humans , Male , Middle Aged , Patient Satisfaction , Recovery of Function , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...